Product specification
| OUTPUT | Voltage(DC) | 15-30V | 31-45V | 46-70V | 71-105V |
| Current(Max.) | 1.75A | 1.29A | 0.8A | 0.66A | |
| Power(Max.) | 40.25W | 40W | 40.02W | 40W | |
| Ripple & noise | ≤600mV | ≤900mV | ≤1400mV | ≤2000mV | |
| Voltage tolerance | ±5% | ||||
| INPUT | Voltage Range | 100-240VAC | |||
| Frequency | 50-60Hz | ||||
| ENVIRONMENT | Operation Temp | -25℃ to +45℃ | |||
| Storage Temp. | -25℃ to +80℃ | ||||
| Operation HUM | 10%-90% | ||||
| SAFETY | Safety certificates | 61347, FCC, CE | |||
| Other | MTBF | >50,000 hours at 80% load and 25℃ | |||
| Dimension | 155X44X31mm | ||||
Specification
The range of input voltage is from 90Vac to 264Vac with a single phase.
Input AC Current, 0.15Amax @ 100-240Vac input & Full load.
The inrush current will not exceed 50A at 100-240Vac input and Max load for a cold start at 25℃.
While input 115Vac and 230Vac, the average efficiency is more than 73.48%. The test point is at 25%, 50%, 75% and 100% of max load respectively.
While input 115Vac or 230Vac and the output is no load, the input power loss must be less than 0.5W.
While input 100~240Vac and capacitance load is 470uF, the adapter can turn on normally and the output is in the rated range.
Output Load Transient Response: the output shall not exceed 10% of the nominal output voltage, load fluctuation: from 20% to 80%, R/S: 0.5A/uS, frequency: 100Hz duration and 8mS at 80%.
Over Current Protection, Short Circuit Protection and Over Voltage Protection.
Drop test: Height: 1m; the product should be fell off on the plank with the thickness of at least 53mm, and the plank should be put on the cement ground or on the ground without flexibility. Random surface in all 3 times.
The MTBF shall be at least 50,000 hours at 25°C, Full load and nominal input condition.
Dielectric Strength (Hi-pot): Primary to Secondary: 4242VDC / 5mAMax / 60second (3 seconds for mass production).
Leakage Current: 0.25mAmax. at 264Vac / 50Hz.
Insulation Resistance: 50MΩ min. at primary to secondary add 500Vdc test voltage.
Our teams’ core values
We operate with honesty and transparency in all our business dealings.
We are committed to pushing the boundaries of renewable energy technology to create a greener future.
We strive for everything we do from product development to customer service.
We believe that teamwork and partnership are most important for partners.
Frequently Asked Questions
What is the input voltage range for this energy storage system?
The system operates within a wide input voltage range from 90Vac to 264Vac (single phase), with a nominal rated input voltage of 100-240Vac at 50-60Hz.
What built-in protection features does the system have?
The system is designed with comprehensive safety mechanisms, including Over Current Protection, Short Circuit Protection, and Over Voltage Protection to ensure reliable operation.
What is the expected lifespan (MTBF) of the product?
The Mean Time Between Failures (MTBF) is rated at a minimum of 50,000 hours under conditions of 25°C ambient temperature, full load, and nominal input.
What are the physical dimensions and weight/drop specifications?
The physical dimensions of the unit are 155 x 44 x 31 mm. It is built to withstand impact, passing drop testing from a height of 1 meter onto a plank with a minimum thickness of 53mm.
What are the operating temperature and environmental limits?
The system operates effectively in temperatures ranging from -25℃ to +45℃. It can be safely stored in temperatures from -25℃ to +80℃, with operation humidity levels between 10% and 90%.
What safety certificates does this product comply with?
This product holds key safety certifications including 61347, FCC, and CE, meeting global compliance standards.