40W Series LED Driver - Reliable Power Supply from China Suppliers | Quality LED Drivers Factory
Energy storage system
Product specification
| OUTPUT | Voltage(DC) | 15-30V | 31-45V | 46-70V | 71-105V |
| Current(Max.) | 1.75A | 1.29A | 0.8A | 0.66A | |
| Power(Max.) | 40.25W | 40W | 40.02W | 40W | |
| Ripple & noise | ≤600mV | ≤900mV | ≤1400mV | ≤2000mV | |
| Voltage tolerance | ±5% | ||||
| INPUT | Voltage Range | 100-240VAC | |||
| Frequency | 50-60Hz | ||||
| ENVIRONMENT | Operation Temp | -25℃ to +45℃ | |||
| Storage Temp. | -25℃ to +80℃ | ||||
| Operation HUM | 10%-90% | ||||
| SAFETY | Safety certificates | 61347, FCC, CE | |||
| Other | MTBF | >50,000 hours at 80% load and 25℃ | |||
| Dimension | 155X44X31mm | ||||
Energy storage system
Specification
- The range of input voltage is from 90Vac to 264Vac with a single phase.
- Input AC Current, 0.15Amax @ 100-240Vac input & Full load.
- The inrush current will not exceed 50A at 100-240Vac input and Max load for a cold start at 25℃.
- While input 115Vac and 230Vac, the average efficiency is more than 73.48%. The test point is at 25%, 50%, 75% and 100% of max load respectively.
- While input 115Vac or 230Vac and the output is no load, the input power loss must be less than 0.5W.
- While input 100~240Vac and capacitance load is 470uF, the adapter can turn on normally and the output is in the rated range.
- Output Load Transient Response: the output shall not exceed 10% of the nominal output voltage, load fluctuation: from 20% to 80%, R/S: 0.5A/uS, frequency: 100Hz duration and 8mS at 80%.
- Over Current Protection, Short Circuit Protection and Over Voltage Protection.
- Drop in: Height: 1m; the product should be fell off on the plank with the thickness of at least 53mm, and the plank should be put on the cement ground or on the ground without flexibility. Random surface in all 3 times.
- The MTBF shall be at least 50,000hours at 25°C, Full load and nominal input condition.
- Dielectric Strength(Hi-pot): Primary to Secondary: 4242VDC / 5mAMax / 60second(3 seconds for mass production).
- Leakage Current: 0.25mAmax. at 264Vac / 50Hz.
- Insulation Resistance: 50MΩ min. at primary to secondary add 500Vdc test voltage.
ELITE
Our teams’ core values
-
FAITHWe operate with honesty and transparency in all our business dealings.
-
INNOVATIONWe are committed to pushing the boundaries of renewable energy technology to create a greener future.
-
EFFORTWe strive for everything we do from product development to customer service.
-
Win-WinWe believe that teamwork and partnership are most important for partners.
FAQ
Frequently Asked Questions
What is the input voltage range for this energy storage system?
The input voltage ranges from 90Vac to 264Vac with a single phase, and operates on a frequency of 50-60Hz.
What safety certifications does the product hold?
The product is certified with 61347, FCC, and CE safety certificates.
What is the average efficiency and power loss under no-load conditions?
The average efficiency is more than 73.48% at 115Vac and 230Vac input. When there is no load, the input power loss is less than 0.5W.
What protective features are integrated into the device?
The system features built-in Over Current Protection, Short Circuit Protection, and Over Voltage Protection.
What is the operating temperature range and durability of the system?
The operating temperature ranges from -25℃ to +45℃. It has a calculated MTBF (Mean Time Between Failures) of at least 50,000 hours at 25°C under full load conditions.