Leave Your Message
Request a Quote
50.4W Series Medical Power Supplies Desktop Type - Trusted China Suppliers and Factory for Quality Solutions
Hot Products

50.4W Series Medical Power Supplies Desktop Type - Trusted China Suppliers and Factory for Quality Solutions

As a leading factory in China, we specialize in the manufacturing of high-quality Medical Power Supplies. Our product range includes desktop models such as the 24W series and 50.4W series, designed to meet the stringent requirements of the medical industry. We are committed to providing reliable and efficient solutions as trusted suppliers of medical power products. Discover our innovative designs that ensure safety and performance for medical applications.

    Energy storage system

    Product Specification

    OUTPUT Voltage(DC) 9V 9.1-14V 14.1-21V 21.1-30V 30.1-48V
    Current(Max.) 5A 4.16A 3.36A 2.3A 1.57A
    Power (Max.) 45W 50W 50.4W 50.4W 50.4W
    Ripple & noise ≤150 mV ≤200 mV ≤200 mV ≤300 mV ≤300 mV
    Voltage tolerance ±5%
    Standby power <0.21W
    INPUT Voltage Range 100-240VAC
    Frequency Range 50-60Hz
    ENVIRONMENT Operation Temp. 0°C to +40°C
    Storage Temp. -20°C to +80°C
    Operation HUM 10% - 90%
    SAFETY Safety Standards 60601, CB, cULus, FCC, CE, TUV Mark, AU plug report
    OTHER MTBF >50,000 hours at 80% load and 25°C
    Dimension 97.5 x 52.5 x 32.0 mm
    Energy storage system

    Specification Details

    • 1. The range of input voltage is from 90Vac to 264Vac with a single phase.

    • 2. The inrush current will not exceed 80A at 100-240Vac input and Max load for a cold start at 25°C.

    • 3. While input 115Vac and 230Vac, the average efficiency is more than 87.72%. The test point is at 25%, 50%, 75% and 100% of max load respectively.

    • 4. While input 115Vac or 230Vac and the output is no load, the input power loss must be less than 0.1W.

    • 5. While input 100~240Vac and capacitance load is 470uF, the adapter can turn on normally and the output is in the rated range.

    • 6. Output Load Transient Response: the output shall not exceed 10% of the nominal output voltage, load fluctuation: from 20% to 80%, R/S: 0.5A/uS, frequency: 100Hz duration and 8mS at 80%.

    • 7. Over Current Protection: I > 3.75A. The output shall hiccup when the over currents applied to the output rail, and shall be self-recovery when the fault condition is removed.

    • 8. The input power shall decrease when the output rail short, the power supply shall no damage, and shall be self-recovery when the fault condition is removed.

    • 9. The power supply shall protection when the output over voltage.

    • 10. Drop in: Height: 1m; the product should be fell off on the plank with the thickness of at least 53mm, and the plank should be put on the cement ground or on the ground without flexibility. Random surface in all 3 times.

    • 11. Burn-in: The power supply shall be burn-in at least 4 Hours under normal input and 80% rated load at 40°C ± 5°C.

    • 12. MTBF Qualification: The MTBF shall be at least 50,000hours at 25°C, Full load and nominal input condition.

    • 13. EMI Standard/EMI : EN55032

    • 14. Safety Accord with IEC60601-1, EN60601-1. Note: AC pins corresponding to relative national standards.

    • 15. Dielectric Strength(Hi-pot): Primary to Secondary: 4242VDC or 3000VAC / 5mAMax / 60second(3 seconds for mass production).

    • 16. Leakage Current: 0.1mAmax. at 264Vac / 50Hz

    • 17. Packing: PE bag, small white box, cardboard, paper case. We could pack our products according to customers’ requirement.

    ELITE

    Why Choose US?

    DYS851 50
    Profession

    20 Years’ R&D Innovation Capability, Offer OEM & ODM Service.

    Strong

    800 Employees Chinese Factory, 50 Professional R&D Engineer, 80 QC Members.

    Service

    Competitive Price, Free Sample, 25 to 40 Working Days Lead Time. It depends on order quantity and the order time.

    Reliable

    Completely certificated.

    Comprehensive

    Battery Chargers, LED Drivers, External Power Supplies Desktop Type, External Power Supplies Fixed wall-plug-in type, External Power Supplies Interchangeable plug type, External Power Supplies USB Chargers, IP67 Waterproof Power Supplies, Medical Power Supplies Desktop type, Medical Power Supplies Fixed wall-plug-in type, Medical Power Supplies Interchangeable plug type, Open Frame Power Supplies, PD Charger, USB Chargers, AC cable, Power Cord, etc.

    Information

    Frequently Asked Questions

    What are the input voltage and frequency ranges for this power supply?
    The standard input voltage range is 100-240VAC (with a maximum operational range of 90Vac to 264Vac single phase) and the input frequency range is 50-60Hz.
    What safety and EMI standards does the product comply with?
    The power supply complies with medical safety standards IEC60601-1 and EN60601-1. It is fully certified with CB, cULus, FCC, CE, TUV Mark, and EN55032 for EMI standards.
    What type of output protections are built into this system?
    It includes Over Current Protection (triggers at I > 3.75A with hiccup mode and self-recovery), Short Circuit Protection (input power decreases, no damage, self-recovery), and Output Over Voltage Protection.
    What is the expected MTBF and lifespan of the unit?
    The MTBF (Mean Time Between Failures) is qualified to be at least 50,000 hours at 25°C ambient temperature, under full load or 80% load conditions.
    What are the standby power loss and efficiency ratings?
    The power supply has a standby power consumption of less than 0.21W (under 0.1W at no-load for 115Vac/230Vac inputs). The average efficiency is rated at more than 87.72% when tested across 25%, 50%, 75%, and 100% load points.
    What options are available for product packaging?
    Standard packaging includes a PE bag, small white box, cardboard dividers, and a paper outer case. Custom packing designs can also be accommodated based on specific client requirements.