Product Specification
OUTPUT |
Voltage(DC) |
9V |
9.1-14V |
14.1-21V |
21.1-30V |
30.1-48V |
Current(Max.) |
5A |
4.16A |
3.36A |
2.3A |
1.57A |
|
Power (Max.) |
45W |
50W |
50.4W |
50.4W |
50.4W |
|
Ripple & noise |
≤150 mV |
≤200 mV |
≤200 mV |
≤300 mV |
≤300 mV |
|
Voltage tolerance |
±5% |
|||||
Standby power |
<0.21W |
|||||
INPUT |
voltage Range |
100-240VAC |
||||
Frequency Range |
50-60Hz |
|||||
ENVIRONMENT |
operation Temp. |
0℃ to +40℃ |
||||
Storage Temp. |
-20℃ to +80℃ |
|||||
operation HUM |
10%-90% |
|||||
SAFETY |
Safety Standards |
60601 |
||||
Other |
MTBF |
>50,000 hours at 80% load and 25℃ |
||||
Dimension |
97.5X52.5X32.0mm |
|||||
Specification Details
- 1. The range of input voltage is from 90Vac to 264Vac with a single phase.
- 2. The inrush current will not exceed 80A at 100-240Vac input and Max load for a cold start at 25℃.
- 3. While input 115Vac and 230Vac, the average efficiency is more than 87.72%. The test point is at 25%, 50%, 75% and 100% of max load respectively.
- 4. While input 115Vac or 230Vac and the output is no load, the input power loss must be less than 0.1W.
- 5. While input 100~240Vac and capacitance load is 470uF, the adapter can turn on normally and the output is in the rated range.
- 6. Output Load Transient Response: the output shall not exceed 10% of the nominal output voltage, load fluctuation: from 20% to 80%, R/S: 0.5A/uS, frequency: 100Hz duration and 8mS at 80%.
- 7. Over Current Protection: I > 3.75A. The output shall hiccup when the over currents applied to the output rail, and shall be self-recovery when the fault condition is removed.
- 8. The input power shall decrease when the output rail short, the power supply shall no damage, and shall be self-recovery when the fault condition is removed.
- 9. The power supply shall protection when the output over voltage.
- 10. Drop in: Height: 1m; the product should be fell off on the plank with the thickness of at least 53mm, and the plank should be put on the cement ground or on the ground without flexibility. Random surface in all 3 times.
- 11. Burn-in: The power supply shall be burn-in at least 4 Hours under normal input and 80% rated load at 40℃ ± 5℃.
- 12. MTBF Qualification: The MTBF shall be at least 50,000hours at 25°C, Full load and nominal input condition.
- 13. EMI Standard/EMI : EN55032
- 14. Safety Accord with IEC60601-1, EN60601-1. Note: AC pins corresponding to relative national standards.
- 15. Dielectric Strength(Hi-pot): Primary to Secondary: 4242VDC or 3000VAC / 5mAMax / 60second(3 seconds for mass production).
- 16. Leakage Current: 0.1mAmax. at 264Vac / 50Hz
- 17. Packing: PE bag, small white box, cardboard, paper case. We could pack our products according to customers’ requirement.
Why Choose US?
20 Years’ R&D Innovation Capability, Offer OEM & ODM Service.
800 Employees Chinese Factory, 50 Professional R&D Engineer, 80 QC Members.
Competitive Price, Free Sample, 25 to 40 Working Days Lead Time. It depends on order quantity and the order time.
Completely certificated.
Battery Chargers, LED Drivers, External Power Supplies Desktop Type, External Power Supplies Fixed wall-plug-in type, External Power Supplies Interchangeable plug type, External Power Supplies USB Chargers, IP67 Waterproof Power Supplies, Medical Power Supplies Desktop type, Medical Power Supplies Fixed wall-plug-in type, Medical Power Supplies Interchangeable plug type, Open Frame Power Supplies, PD Charger, USB Chargers, AC cable, Power Cord, etc.
Frequently Asked Questions (FAQ)
What is the input voltage range for this power supply?
The input voltage ranges from 90Vac to 264Vac (nominal 100-240VAC) with a single phase, operating at a frequency range of 50-60Hz.
Does this power supply feature over-current and short-circuit protection?
Yes, it features Over Current Protection (I > 3.75A) which enters hiccup mode and self-recovers once the fault is removed. It also has short-circuit protection and over-voltage protection, ensuring no damage to the power supply.
What safety and EMI standards does the product comply with?
The product is designed to accord with medical safety standards IEC60601-1 and EN60601-1. It is fully certified with CB, cULus, FCC, CE, and TUV Mark. It also complies with the EN55032 EMI standard.
What is the MTBF (Mean Time Between Failures) of this power supply?
The qualified MTBF is at least 50,000 hours under conditions of 25°C ambient temperature, full load, and nominal input.
What are the operational temperature and humidity limits?
The operating temperature range is from 0℃ to +40℃ with an operating humidity of 10% to 90%. For storage, it can withstand temperatures from -20℃ to +80℃.
Do you provide OEM and ODM services?
Yes, we leverage 20 years of R&D innovation capability to offer comprehensive OEM and ODM services. Custom packaging solutions (PE bags, white boxes, cardboard/paper cases) are also available according to customer requirements.